Standard or regulation
ASME A17.1 / CSA B44: Safety Code for Elevators and Escalators
The harmonized U.S. and Canadian safety code for elevators and escalators. It includes requirements for emergency two-way communication from inside the car to authorized personnel who can act on a call for help.
- Issuing organization
- American Society of Mechanical Engineers / CSA Group
- Edition
- Issued in revised editions on a multi-year cycle. Recent editions have added requirements around message display and video, so the adopted edition materially changes what is required.
- Jurisdictions
- United States; Canada; where adopted by the authority having jurisdiction
Scope
Applies to elevator installations where adopted by the jurisdiction. Relevant to POTS replacement because the emergency communication path from the car has historically been an analog telephone line, and replacing it changes a code-governed element.
Key considerations
Two-way communication must reach someone who can act
The requirement is not merely that a call is placed, but that it reaches authorized personnel able to respond. A replacement path has to preserve that end-to-end outcome, not just dial tone.
Monitoring and failure detection
Recent editions address monitoring of the communication means so a failure is identified. A replaced line that can be supervised and alerted on is generally easier to demonstrate than one that cannot.
Backup power
Emergency communication must function when a passenger is trapped, which is frequently during a power failure. Integrated battery backup in the replacement appliance is directly relevant.
Inspector acceptance
Elevator inspectors and the AHJ determine acceptability. An elevator can be taken out of service if the emergency communication path is not acceptable, so coordinate before migrating.
Elevator lines are usually the first thing to migrate and the last thing you want to get wrong. A rejected communication path can put the car out of service.
Frequently asked questions
Cellular paths are used in practice, but acceptability depends on the adopted code edition and the AHJ's determination for that installation. Confirm before migrating, since the consequence of a rejected path is an out-of-service elevator.
A trapped passenger cannot summon help, and the elevator may be red-tagged by an inspector. This is why elevator lines are typically sequenced first in a migration.
Recent editions address monitoring of the communication means. Which requirements apply depends on the edition your jurisdiction has adopted.
Related to this standard
Products
Solutions
Certifications
Topics
Official sources
- ASME A17.1/CSA B44 Safety Code for Elevators and Escalators (opens in a new tab) — American Society of Mechanical Engineers
Last reviewed .
Ready to retire your copper lines?
Talk to a DataRemote specialist about replacing your POTS lines before your carrier shuts copper down.